APC | SKU:
BK500
APC Back-UPS CS Battery Backup System, 6 Outlets, 500 VA, 480 J - BK500
$171.67
Unit price
/
Unavailable
Shipping calculated at checkout.
APC Back-UPS CS Battery Backup System, 6 Outlets, 500 VA, 480 J - BK500 is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Care information
Care information
Manufacture Warranty
Delivery and Shipping
Delivery and Shipping
Standard Shipping: 3-5 Business days
Express Shipping: 1-2 Business days
Description
Description
Features
• Battery-protected and surge-only outlets.• Dataline Surge Protection.
• Power conditioning.
• Audible alarms.
• Automatic restart of loads after UPS shutdown.
• Automatic battery self-test.
• LED status indicators.
• Battery replacement without tools.
• Transformer-block spaced outlets.
• Resettable circuit breakers.
• Dataline Surge Protection provides protection of connected equipment on the data lines. Automatic restart of loads after UPS shutdown upon the return of utility power for exceptional convenience.
• Combination of battery-protected and surge-only outlets reserves power capacity for connected equipment that requires battery back-up. Dataline Surge Protection provides protection of connected equipment on the data lines. Power conditioning protects connected loads from surges, spikes, lightning, and other disturbances. Audible alarms delivers notification of changing utility power and UPS conditions. Automatic restart of loads after UPS shutdown upon the return of utility power for exceptional convenience. Automatic battery self-test ensures early detection of a battery that needs to be replaced.
• Combination of battery-protected and surge-only outlets reserves power capacity for connected equipment that requires battery back-up. Dataline Surge Protection provides protection of connected equipment on the data lines. Power conditioning protects connected loads from surges, spikes, lightning, and other disturbances. Audible alarms delivers notification of changing utility power and UPS conditions. Automatic restart of loads after UPS shutdown upon the return of utility power for exceptional convenience. Automatic battery self-test ensures early detection of a battery that needs to be replaced. LED status indicators helps you to quickly and easily understand UPS status. Battery replacement without tools for reduced risk of load disruption. Transformer-block spaced outlets keeps equipment secure without blocking access to other receptacles. Resettable circuit breakers enables quick recovery from UPS overload events.
• Reliable backup power.
• Protection from surges and spikes.
• Automatic battery self-test.
• Hot-swappable batteries.
• Audible alarms.
• Protect computers and other sensitive electronics with reliable backup power. Power conditioning protects connected loads from surges, spikes, lightning, and other disturbances. Automatic battery self-test ensures early detection of a battery that needs to be replaced. Hot-swappable batteries deliver clean, uninterrupted power to protected equipment while batteries are being replaced. Audible alarms provide notification of changing utility power and UPS conditions. Combination of battery-protected and surge-only outlets reserves power capacity for connected equipment that requires battery back-up.
•
Specification
| Global Product Type | Backup Systems |
| System VA | 500 VA |
| Backup Time at Half Load | 13.9 min @ 150 W |
| Automatic Voltage Regulation (AVR) | No |
| Battery Recharge Time | 8 h |
| Connected Equipment Guarantee/Warranty | $100,000 Equipment Protection Policy |
| Backup Time at Full Load | 2.4 min @ 300 W |
| Connector/Port/Interface | DB9 |
| Connector/Port/Interface | RS232 |
| Connector/Port/Interface | USB |
| Joules Of Surge Protection | 480 J |
| Number of Outlets | 6 |
| React Time | Instantaneous |
| Cord Length | 6 ft |
| Telephone/Internet Protection | Fax |
| Telephone/Internet Protection | Modem |
| Telephone/Internet Protection | Phone |
| Color(s) | Beige |
| Width | 3.6 |
| Height | 6.5 |
| Depth | 11.2 |
| Backup Systems Alarm(s) | Audible |
| Emergency Power Off (EPO) | No |
| Input Frequency | 50-60 Hz |
| Number of Outlets/Type | 3 UPS/Surge |
| Number of Outlets/Type | 3 Surge Only |
| Backup Run Time | 15 min |
| Compliance Standards | cUL Listed |
| Compliance Standards | FCC Class B Certified |
| Compliance Standards | UL Listed |
| Pre-Consumer Recycled Content Percent | 0% |
| Post-Consumer Recycled Content Percent | 0% |
| Total Recycled Content Percent | 0% |
| Disclaimer Statement | Run Time based on a load of 150 W. |
Classification
| Product_Class_Category | SURGE, UPS MACHINES |
| Assembly_Code | N |
| Recycle_Indicator | N |
| Green_Indicator | N |
| EPACPGCompliant_Code | N |
| Prop_65_Indicator | N |
| Prop_65_Label_Indicator | N |
| Business Unit | U |
| Shelf Life | 0 |
| MSDS_Indicator | Y |
| UNSPSC | 39121011 |
| Non_Returnable_Code | A |
| Status_Code1 | N |
| Status_Code2 | Z |
| Status_Code3 | N |
| EPA List N | N |
| EPA Registration | N |
| FDA Certified | N |
| Pesticide Product | N |
| TSCA 6(h) | N |
| TSCA 12(b) | N |
| Marketplace Restriction | NORST |
| RFEA Status | Not Apply |
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.



